At Orbit NSN, we offer an expansive inventory of Analyzer Clinical C components by Qbc Diagnostics Llc, including part number 4451-QBCII, and many others. On this page, you can complete and submit a quote request form for this part number and others with the NSN 6630012346794 to receive a customized solution within 15 minutes or less of submission. All we ask is that you include relevant information while filling out this form, such as your desired part quantity and budget parameters, so our dedicated staff can best respond with a quote that suits your needs and restrictions alike.
Note : We Will Not Share Your Information To Any Third Parties.
Quality is the cornerstone of our operations at Orbit NSN, and as such, we proudly operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation, in addition to adhering to a strict NO CHINA SOURCING policy. To make your search simple, our catalogs feature items with CAGE Code 4AZY5 and FSC 6630 Chemical Analysis Instruments so that you always know you are procuring the exact items you need. To learn more about components with the NSN 6630-01-234-6794, such as this part manufactured by Qbc Diagnostics Llc, give us a call or email at any time, and a dedicated team member will be more than happy to assist you however they can through the procurement process. Get started today to see why our customers continue to rely on our top-notch products and services for all their operational needs.
MRC | Criteria | Characteristic |
---|---|---|
ELEC | Voltage In Volts | 120.0 AND 220.0 |
CXCY | Part Name Assigned By Controlling Agency | ANALYZER, CLINICAL CHEMISTRY |
AKYD | Accessory Components And Quantity | ELECTRO-OPTICAL MAGNIFICATION READER 1; WORK STATION 1; VENOUS-BLOOD PIPETTER 1 |
ACZB | Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
FEAT | Special Features | MICROPROCESSOR CONTROLLED ELECTRO-OPTICAL INSTRUMENT FOR MEASURING PACKED CELL VOLUMES AND CONVERTING TO RELATIVE VALUES;COMPONENTS INC.75X MONOCULAR MICROSCOPE,ROTATING TUBE CARTRIDGE ASSY;OPICAL ENCODER;UV ILLUMINATOR LAMP;VARIOUS LENSES AND FILTERS TO CAUSE STAINED WHITE CELLS AND PLATELETS TO FLUORESCE;12 PLACE HEMATOCRIT CENTRIFUGE WITH HEAD COVER,FIXED FIVE MINUTE TIMER;12,000 RPM SPEED CAPACITY;AND RCF OF 14,387 X G;TWO POSITION PIPETTER WITH FIXED VOLUME OF 111.1 MICROLITERS;WORK STATION WITH NUMBERED SLOTS FOR CAPILLARY TUBES;WELLS FOR WHOLE BLOOD TUBES AND RACK FOR STORAGE OF PIPETTER;OPERATION METHOD:ELECTRIC;EXTERIOR CONTAINER QUANTITY:1;THE NUMBER OF ALTERNATING CURRENT PHASE:TWO |
SUPP | Supplementary Features | CONT C/O TWO SEALED CALIBRATION CHECK TUBES; ONE VENOUS,ONE CAPILLARY; ONE PAIR FORCEPS; SPARE PIPETTER "O" RINGS AND GREASE,SPARE LAMPS FUSES,TWO THRUST PIVOTS,ONE 5/64 IN. HEX KEY AND TEST GUIDE; CAPABLE OF PERFORMING THE FOLLOWING QUANTITATIVE FUNCTIONS ON A CENTRIFUGAL BLOOD TUBE; HEMOGLOBIN,HEMATOCRIT,PLATELET COUNT,WHITE BLOOD COUNT,GRANULOCYTE COUNT,AND LYMPHOCYTE-MONOCYTE COUNT; FOR CAPILLARY MICROHEMATOCRIT TUBE KIT ORDER 6630-01-233-7594; FOR VENOUS MICROHEMATOCRIT TUBE KIT,ORDER 6630-01-233-7593 AND VENOUS HEMATOCRIT TUBE KIT 6630-01-233-9592; REQUISITIONER SHOULD SPECIFY THE VOLTAGE AND FREQUENCY REQUIRED |
MRC | Decoded Requirement | Clear Text Reply |
ALUE | Universal Medical Device Nomenclature System Code | 16298 |
ACDC | Current Type | AC |